
[2024] Use Valid New H19-338-ENU Test Notes & H19-338-ENU Valid Exam Guide
H19-338-ENU Actual Questions Answers PDF 100% Cover Real Exam Questions
NEW QUESTION # 41
Which of the following are NOT true about OceanStor Dorado V6? (Multiple choice)
- A. Controller failure tolerance of 7 out of 8 (controllers for every model)
- B. NVMe for every model
- C. Latency as low as 0.7
- D. OPS up to 20 million
Answer: B,C
NEW QUESTION # 42
Among the Dorado series storage systems, which back-end technology provides the shortest theoretical latency?
- A. NVMe
- B. SAS
- C. PCIe
Answer: A
NEW QUESTION # 43
The full-stripe write technology supported by Dorado can effectively improve SSDs' service life.
- A. False
- B. True
Answer: B
NEW QUESTION # 44
Which of the following consistency groups (CGs) can be created based on protected groups of Dorado V6? (Multiple choice)
- A. Clone CG
- B. HyperMetro CG e. 3DC CG
- C. Snapshot CG
- D. Asynchronous remote replication CG
Answer: A,B,C
NEW QUESTION # 45
In an OceanStor Dorado V6 Architecture with two controller enclosures and eight controllers, which scenarios are supported for high availability? (Multiple Choice)
- A. Tolerance of a single controller enclosure failure
- B. Tolerance of simultaneous failures of any two controllers
- C. Tolerance of simultaneous failures for any three controllers
- D. Tolerance of simultaneous failures for seven controllers
Answer: B,C
NEW QUESTION # 46
By March 2021, how many limes has Huawei CloudFabric solution been awarded Gartner's "Customer Choice"?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: A
Explanation:
Explanation
Huawei CloudFabric solution has been awarded Gartner's "Customer Choice" three times by March 2021.
According to the Huawei CloudFabric Solution Wins Gartner Peer Insights Customers' Choice for Third Consecutive Year article, Huawei CloudFabric solution received this honor in 2019, 2020, and 2021.
NEW QUESTION # 47
Which software architecture does the OceanStor V5 use?
- A. Block-based FS architecutre
- B. Parallel block and FS architecture
- C. FS-based block architecture
Answer: B
NEW QUESTION # 48
Which method can be used to upgrade a Dorado active-active (HyperMetro) solution to a 3DC solution?
- A. Synchronous replication
- B. Volume mirroring
- C. Active-active
- D. Asynchronous replication
Answer: D
NEW QUESTION # 49
Which of the following features make OceanStor capable of storing PACS data over a 15-year period? (Multiple choice)
- A. Simplified management
- B. Elastic scalability
- C. Intelligent lifecycle management
- D. Security and reliability
Answer: A,B,C,D
NEW QUESTION # 50
HyperMetro uses the quorum server mode. If all replication links between two sites are down, what are the Health Status, Running Status, and Link Status of the HyperMetro pair?
- A. Faulty, To be synchronized, Link down
- B. Faulty. Normal. To be recovered
- C. Abnormal, Faulty. ...
Answer: C
NEW QUESTION # 51
Which technique is used to protect end-to-end data integrity?
- A. CRC
- B. SHA
- C. DIX+T10
Answer: C
NEW QUESTION # 52
Which of the following is the specifications supported by the RU-5G-101?
- A. Independent deployment
- B. 500m POE
- C. Number of SIMs supported 2 x SIMs
Answer: A
Explanation:
Explanation
RU-5G-101 supports independent deployment. According to the Huawei RU-5G-101 Datasheet2, RU-5G-101 is a high-speed wireless WAN access component that provides 5G wireless broadband access services for enterprises to implement wireless high-bandwidth data transmission. An RU-5G can be deployed independently to provide basic router functions.
NEW QUESTION # 53
Unity XT supports full configuration of NVMe SSDS.
- A. False
- B. True
Answer: A
NEW QUESTION # 54
Which are the key technologies of SmartMatrix 3.0? (Multiple Choice)
- A. FC Front-end Interconnect I/O Module (FC FIM)
- B. iSCSI and NAS FIM
- C. Back-end Interconnect I/O Module (BIM)
- D. Continuous cache mirroring
Answer: A,C,D
NEW QUESTION # 55
Which of the following are storage protocols for host connection in SAN? (Multiple choice)
- A. SAS
- B. FC
- C. iSCSI
- D. NoF (NVMe over Fabric)
Answer: B,C,D
NEW QUESTION # 56
Which of the following are benefits of front-end interconnect (shared) I/O modules? (Multiple choice)
- A. Direct data dispatch to the distributed controllers through front-end modules in one controller enclosure.
- B. Host path loss prevention in the event of controller failure, controller hard/software upgrades, and even single FC 1 between host and storage.
- C. Storage sysadmins are needed to ensure the multipath software in servers runs online before controller upgrades.
- D. Fewer front-end modules and host links needed.
Answer: B,D
NEW QUESTION # 57
What is the purpose of using sequential I/Os to overwrite all LUNs before testing Dorado performance?
- A. To provide better performance
- B. To ensure correct deduplication and compression ratios
- C. To ensure that all space of thin LUNs is allocated so read performance is close to that in actual scenarios
Answer: A
NEW QUESTION # 58
What is the name of the OceanStor Dorado V6 storage architecture?
- A. ASIC
- B. SmartMatrix
- C. Virtual Matrix
Answer: B
NEW QUESTION # 59
What are the benefits of the multi-stream technology supported by Dorado? (Multiple choice)
- A. Longer SSD service life
- B. Less write application
- C. No garbage collection overhand on SSDs.
Answer: A,B,C
NEW QUESTION # 60
Which statements about FusionStorage are true? (Multiple Choice)
- A. It stores metadata in metadata nodes.
- B. It provides background data consistency checks.
- C. It employs a distributed cluster architecture.
- D. It can be scaled out to a maximum of 4096 nodes.
Answer: A,B,C,D
NEW QUESTION # 61
Which of the following are the strengths of the next-generation NetEngine AR routers?
- A. Incorporates iPath (application-based intelligent traffic steering 8. optimization) and A-FEC {no frame freezing or artifacts even at a 20% packet loss rate)
- B. Incorporates an industry-leading CPU+NP architecture, providing industry-lea ding L3 to L7 full-service efficient processing
- C. Offers three times the industry average performance based on x86
- D. Features multi-mode ZTP on-demand network orchestration; real-time fault alarms and 45+ visualized reports
Answer: A,B,C,D
Explanation:
Explanation
next-generation NetEngine AR routers are intelligent edge routers that provide comprehensive services for enterprises, such as WAN access, SD-WAN, VPN, voice, video, security, cloud interconnection, and IoT .
They have several strengths that differentiate them from other products in the market, such as:
Incorporating an industry-leading CPU+NP architecture, providing industry-leading L3 to L7 full-service efficient processing. The CPU+NP architecture combines the advantages of both CPU-based general-purpose processing and NP-based hardware acceleration, enabling high-performance processing of various services at different layers .
Incorporating iPath (application-based intelligent traffic steering & optimization) and A-FEC {no frame freezing or artifacts even at a 20% packet loss rate). iPath is a technology that intelligently steers traffic based on application types, quality requirements, link conditions, and policies, optimizing the user experience and resource utilization . A-FEC is a technology that enhances the error correction capability of video streams, ensuring smooth video transmission even under high packet loss scenarios .
Offering three times the industry average performance based on x86. The next-generation NetEngine AR routers use x86 processors that deliver high computing power and scalability, enabling them to support more services and users with lower power consumption .
Featuring multi-mode ZTP on-demand network orchestration; real-time fault alarms and 45+ visualized reports. The next-generation NetEngine AR routers support zero-touch provisioning (ZTP), which simplifies the network deployment and management process by automatically discovering, registering, configuring, and upgrading devices . They also support real-time fault alarms and 45+ visualized reports that provide comprehensive network monitoring and analysis capabilities .
NEW QUESTION # 62
Enabling the Fast Write function of replication links between storage arrays can reduce the amount of data to be transmitted by 50%
- A. False
- B. True
Answer: B
NEW QUESTION # 63
ClouEngine S1270OE-)8 provides various types of line processing unit (LPUs), including X5E, X5S, X6E, X6H, and X6S series. How many LPU slots does a CloudEngine S1270OE-O8 have?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: D
Explanation:
Explanation
CloudEngine S1270OE-O8 provides eight LPU slots, four SFU slots, two MPU slots, two CMU slots, and six power module slots1.
NEW QUESTION # 64
......
Huawei H19-338-ENU (HCPP-Storage) Certification Exam is a globally recognized certification program that is designed to validate the skills and knowledge of IT professionals in the storage solutions field. HCPP-Storage certification is offered by Huawei Technologies Co. Ltd., a leading global provider of information and communications technology (ICT) infrastructure and smart devices.
Huawei H19-338-ENU (HCPP-Storage) Certification Exam is a comprehensive exam that covers a wide range of topics related to storage technology. Some of the key topics covered in H19-338-ENU exam include storage systems architecture, storage networking, data protection and management, and storage virtualization. H19-338-ENU exam also covers key technologies such as cloud storage, big data storage, and software-defined storage.
Huawei H19-338-ENU (HCPP-Storage) Certification Exam is designed to test the knowledge and skills of IT professionals who want to specialize in storage. HCPP-Storage certification exam is ideal for those who work in roles such as storage administrators, storage engineers, and storage architects. H19-338-ENU exam covers a range of topics related to storage, including storage system planning and design, storage system deployment and management, backup and disaster recovery, and storage system troubleshooting and optimization.
H19-338-ENU Exam questions and answers: https://actualanswers.testsdumps.com/H19-338-ENU_real-exam-dumps.html
